3F Dìagon FCL
Code 23787
L<1500 cd/m² 65°
Average luminance <1500 cd/m² for radial angles >65°.
Installation Interdistance Transv.D = 1.40 x hu ‑ Long.D = 1.40 x hu.
Rhomboidal lenses with differentiated surfaces, etched and prismatic to optimise the orientation of the luminous flux, in transparent methacrylate (PMMA).
3F Dìagon 599x599 ‑ ON/OFF electronic wiring 230V‑50/60Hz
Code
Item
W
lm
K
CRI
L x A x H
IP
23785
3F Diagon FCL 19W/840 599x599
21
3354
4000
>80
599x599x60
43
23786
3F Diagon FCL 25W/840 599x599
28
4250
4000
>80
599x599x60
43
3F Dìagon 599x599 ‑ DALI electronic wiring 230V‑50/60Hz
Code
Item
W
lm
K
CRI
L x A x H
IP
23787
3F Diagon FCL 19W/840 DALI 599x599
21
3354
4000
>80
599x599x60
43
23788
3F Diagon FCL 25W/840 DALI 599x599
28
4250
4000
>80
599x599x60
43
3F Dìagon 599x599 ‑ EP maintained emergency wiring, 1hr duration with 24hrs recharge
Code
Item
W
lm
K
CRI
L x A x H
IP
23789
3F Diagon FCL 19W/840 EP 599x599
22
3354
4000
>80
599x599x60
43
23790
3F Diagon FCL 25W/840 EP 599x599
29
4250
4000
>80
599x599x60
43
3F Dìagon FCH
Code 23797
L<1500 cd/m² 65°
Average luminance <1500 cd/m² for radial angles >65°.
Installation Interdistance Transv.D = 1.40 x hu ‑ Long.D = 1.40 x hu.
Rhomboidal lenses with differentiated surfaces, etched and prismatic to optimise the orientation of the luminous flux, in transparent methacrylate (PMMA).
3F Dìagon 599x599 ‑ ON/OFF electronic wiring 230V‑50/60Hz
Code
Item
W
lm
K
CRI
L x A x H
IP
23795
3F Diagon FCH 19W/840 599x599
21
3354
4000
>80
599x599x60
43
23796
3F Diagon FCH 25W/840 599x599
28
4250
4000
>80
599x599x60
43
3F Dìagon 599x599 ‑ DALI electronic wiring 230V‑50/60Hz
Code
Item
W
lm
K
CRI
L x A x H
IP
23797
3F Diagon FCH 19W/840 DALI 599x599
21
3354
4000
>80
599x599x60
43
23798
3F Diagon FCH 25W/840 DALI 599x599
28
4250
4000
>80
599x599x60
43
3F Dìagon 599x599 ‑ EP maintained emergency wiring, 1hr duration with 24hrs recharge
Code
Item
W
lm
K
CRI
L x A x H
IP
23799
3F Diagon FCH 19W/840 EP 599x599
22
3354
4000
>80
599x599x60
43
23800
3F Diagon FCH 25W/840 EP 599x599
29
4250
4000
>80
599x599x60
43
3F Dìagon FP
Code 23770
L<1500 cd/m² 65°
Average luminance <1500 cd/m² for radial angles >65°.
Installation Interdistance Transv.D = 1.40 x hu ‑ Long.D = 1.40 x hu.
Rhomboidal lenses with differentiated surfaces, etched and prismatic to optimise the orientation of the luminous flux, in transparent methacrylate (PMMA).
3F Dìagon 599x599 ‑ ON/OFF electronic wiring 230V‑50/60Hz
Code
Item
W
lm
K
CRI
L x A x H
IP
24048
3F Diagon FP 19W/840 599x599
21
3354
4000
>80
599x599x60
43
24049
3F Diagon FP 25W/840 599x599
28
4250
4000
>80
599x599x60
43
3F Dìagon 599x599 ‑ DALI electronic wiring 230V‑50/60Hz
Code
Item
W
lm
K
CRI
L x A x H
IP
24050
3F Diagon FP 19W/840 DALI 599x599
21
3354
4000
>80
599x599x60
43
24051
3F Diagon FP 25W/840 DALI 599x599
28
4250
4000
>80
599x599x60
43
3F Dìagon 599x599 ‑ EP maintained emergency wiring, 1hr duration with 24hrs recharge
Code
Item
W
lm
K
CRI
L x A x H
IP
24052
3F Diagon FP 19W/840 EP 599x599
22
3354
4000
>80
599x599x60
43
24053
3F Diagon FP 25W/840 EP 599x599
29
4250
4000
>80
599x599x60
43
3F Dìagon FP Soft UGR
Code 23850
L<3000 cd/m² 65°
Average luminance <3000 cd/m² for angles >65°.
Installation Interdistance Transv.D = 1.20 x hu ‑ Long.D = 1.20 x hu.
Rhomboidal lenses with differentiated surfaces, etched and prismatic to optimise the orientation of the luminous flux, in opal methacrylate (PMMA).
3F Dìagon 599x599 ‑ ON/OFF electronic wiring 230V‑50/60Hz
Code
Item
W
lm
K
CRI
L x A x H
IP
23853
3F Diagon FP 25W/840 SOFT UGR 599x599
28
3679
4000
>80
599x599x60
43
3F Dìagon 599x599 ‑ DALI electronic wiring 230V‑50/60Hz
Code
Item
W
lm
K
CRI
L x A x H
IP
23855
3F Diagon FP 25W/840 DALI SOFT UGR 599x599
28
3679
4000
>80
599x599x60
43
3F Dìagon 599x599 ‑ EP maintained emergency wiring, 1hr duration with 24hrs recharge
Code
Item
W
lm
K
CRI
L x A x H
IP
23854
3F Diagon FP 25W/840 EP SOFT UGR 599x599
29
3679
4000
>80
599x599x60
43
ILLUMINOTECHNICAL
Direct symmetric distribution.
Lifetime (L75/B10): 100000 h. (tq+25°C)
Photobiological safety RG0.
SOURCE
Squared LED modules.
Colour initial tolerance (MacAdam): SDCM 3.
MECHANICAL
Housing in hot‑galvanised steel, painted in white polyester.
Honeycombed diagonal screen in white anti‑glare polycarbonate.
Height only 30 mm.
The FP (For Plasterboard) version is dedicated to plasterboard false ceilings.
The FCL (For Complanar Low) version is dedicated to plasterboard with metal panels and low structures.
The FCH (For Complanar High) version is dedicated to plasterboard with metal panels and high structures.
For all versions, spring fixing in stainless steel.
ELECTRICAL
In compliance with EN 60598‑1.
Compliance with the EN 60598‑2‑22 standard for power supply from a centralised CPSS emergency system must be verified in the technical data sheets of each individual device on our website.
The luminaires with EP permanent emergency wiring on board comply with EN 60598‑2‑22 standard, high risk areas excluded.
Quick connection.
INSTALLATION
Pull‑up installation.
Do not hesitate to contact our Sales Network or our Technical Offices to check the compatibility of the FCH and FCL models with the various types of metallic false ceilings.
APPLICATIONS
FCL, FCH, FP versionsEnvironments: staterooms, with VDTs, offices.
Environments with exacting visual tasks, where diffused soft light for optimum visual comfort is required.
Version FP Soft UGREnvironments where soft diffuse light is required for optimal visual comfort and total shielding of the source.
LIGHT MANAGEMENT
The DALI products can be controlled with 3F Easy Dim or 3F Smart Dimming technology.
ON REQUEST
- different power levels, colour rendering indices and colour temperatures
- wiring: twin‑circuit, CLO
- luminaires for pull‑up installation with brackets
- 3F Tunable White versione
- 3F Dìagon Soft UGR, for FCL and FCH versions
- emergency versions
Anti‑fall safety cable for fixing the housing to the building structure.
Length 2.5 m.
Code
Item
A0702
Suction cup for Diagon maintenance
Suction cup to extract "3F Dìagon" installed in abutment.
To be used in false ceilings with metal panels, where the space between the luminaire and the surrounding panels does not allow the use of other tools.