Yes
No
References
Search
my3F
en
Insert login and password to be identified
Remember me
Enter
Products
 | 
 | 
 | 
3F Linda Transparent
Models
Characteristics
Accessories
3F Linda Transparent
Code 58856
Transparent polycarbonate housing.
Snug fit safety snap‑lock clips in stainless steel.
ON/OFF electronic wiring 230V‑50/60Hz
Code
Item
W
lm
K
CRI
L x A x H
IP
58852
3F Linda LED Lite TR 1x12W L660
14
2033
4000
>80
660x100x100
66
58853
3F Linda LED Lite TR 1x19W L1270
19
2938
4000
>80
1270x100x100
66
58854
3F Linda LED Lite TR 1x23W L1570
23
3548
4000
>80
1570x100x100
66
58855
3F Linda LED Lite TR 2x16W L1270
31
4634
4000
>80
1270x160x100
66
58856
3F Linda LED Lite TR 2x20W L1570
41
6178
4000
>80
1570x160x100
66
ILLUMINOTECHNICAL
Controlled symmetric distribution.
Lifetime (L75/B10): 80000 h. (tq+25°C)
Photobiological safety RG0.
SOURCE
Linear LED modules.
Colour initial tolerance (MacAdam): SDCM 3.
MECHANICAL
Housing in transparent self‑extinguishing V2 polycarbonate, injection moulded.
Ecologic anti‑aging injected sealing gasket.
Gear‑holder reflector in hot‑dip galvanised steel, painted with white polyester base.
Diffuser in self‑extinguishing V2 polycarbonate, photo‑engraved interior, UV stabilised, injection moulded with smooth outer surface.
Snug fit safety snap‑lock clips for diffuser mounting in stainless steel, screwdriver opening.
Fixing brackets in stainless steel.
ELECTRICAL
In compliance with EN 60598‑1.
Compliance with the EN 60598‑2‑22 standard for power supply from a centralised CPSS emergency system must be verified in the technical data sheets of each individual device on our website.
APPLICATIONS
Dry, dusty indoor environments, subject to occasional water splashes.
Environments: transit areas, parking lots.
Environments where soft diffuse light is required for optimal visual comfort.
Virtually shatterproof polycarbonate compatibly with the fumes / atmospheres that compromise the elasticity of plastic materials.
Not suitable in environments where chlorine fumes, ligroin, hydrocarbon mixtures, mineral oil vapours or fumes of lubricating emulsions to cool down machine tools are present.
Not suitable for installation on surfaces subject to important vibrations, exposed to weather conditions, on ropes or poles.
Suitable product for food production plants (HACCP), IFS (Food Version 6), BRC (GSFS Food Version 7).
Suitable for illumination of public car parks and parking grounds referred to DIN 67528:2018‑04.
WARNING
Fixture not suitable for cold stores with an ambient temperature <0°C and/or relative humidity >85%.
ON REQUEST
  • different colour rendering indices and colour temperatures
  • wiring: dimmable, CLO, class II
  • linear LED modules, with special protection against aggressive chemically‑volatile substances, for standard LED technology
  • emergency versions
Code
Item
A0660
Suspension with adjustment - 1m
A0661
Suspension with adjustment - 2 m
A0662
Suspension with adjustment - 3 m
A0663
Suspension with adjustment - 4 m
A0664
Suspension with adjustment - 5 m
A0665
Suspension with adjustment - 6 m
Suspension with regulator, galvanised steel cable 1.5 mm diameter, load 15 kg.
Attention: each product requires two suspensions with regulator.
Code
Item
A0449
15 GZI w/brack.+ hooks Linda L300
A0450
15 RIT w/bra.+hooks Linda L660-1270-1570
Pair of brackets and hooks in stainless steel, with nuts and bolts for fixing to 3F Linda, for ceiling or wall‑mounting, single and twin‑lamp luminaires.
Minimum tilt angle = 45°.
Code
Item
A0451
15 MBI w/brack.+ hooks Linda L300
A0452
15 FBR w/bra.+hooks Linda L660-1270-1570
Pair of brackets and hooks in stainless steel, with nuts and bolts for fixing to 3F Linda, for wall‑mounting, single and twin‑lamp luminaires.
Code
Item
A0462
13 GSI (pair of susp. hooks Linda L300)
A0463
13 TRM pair of susp.hooks Linda
Pair of stainless steel hooks for suspended installation, with cable clip and nuts and bolts for installation to 3F Linda.
Code
Item
A0455
Wireguard 180x1330 3F Linda
Installation instructions download
A0456
Wireguard 180x1630 3F Linda
Installation instructions download
A0457
Wireguard 280x1330 3F Linda/3F Beta
Installation instructions download
A0458
Wireguard 280x1630 3F Linda/3F Beta
Installation instructions download
Wire‑guard for applications in dry environments, against shocks coming from any directions, galvanised steel rod Ø 5 mm.
Only for luminaires fixed without hooks.
Code
Item
A0187
Anti-condensation cable gland
Installation instructions download
Anti‑condensation diffuser cable gland.
Recommended for installations in environments with temperature sudden changes or subject to condensation.
Code
Item
A0521
Reducing sealing ring diam.8mm
Reducing sealing ring, dedicated to the use of cables with an external diameter of up to 8 mm.
Code
Item
A0464
26 CSG (pictogram P1 Linda L300)
A0465
26 MTH (pictogram P1 Linda L660)
Pictograms for warning signs to be applied on emergency luminaire's diffusers 160 mm wide.
Pictogram, 135 mm high, 240 mm long for L300 luminaires, 605 mm long for L660 luminaires.
Pictograms complying with European standards concerning health and safety signals on the workplace.
Code
Item
A0466
26 DVI (pictogram P2 Linda L300)
A0467
26 MVL (pictogram P2 Linda L660)
Pictograms for warning signs to be applied on emergency luminaire's diffusers 160 mm wide.
Pictogram, 135 mm high, 240 mm long for L300 luminaires, 605 mm long for L660 luminaires.
Pictograms complying with European standards concerning health and safety signals on the workplace.
Code
Item
A0468
26 GZM (pictogram P3 Linda L300)
A0469
26 PXN (pictogram P3 Linda L660)
Pictograms for warning signs to be applied on emergency luminaire's diffusers 160 mm wide.
Pictogram, 135 mm high, 240 mm long for L300 luminaires, 605 mm long for L660 luminaires.
Pictograms complying with European standards concerning health and safety signals on the workplace.
Code
Item
A0434
Safety screw locking Linda - 20 pcs
The pack contains 20 pieces.
A0435
Safety screw locking Linda - 100 pcs
The pack contains 100 pieces.
Safety screw for 3F Linda locking bracket
Instruments
lightUpdate
The information, at the speed of Light.
Subscribe to lightUpdate to keep in touch with 3F Filippi: news, events and product news delivered to your mailbox.
Head office and factory
3F Filippi S.p.A.
Via del Savena 28, Z.I. Piastrella
40065 Pian di Macina, Pianoro (Bologna), Italy
Tax Code. 01033260371 - VAT no. IT00529461204
Share Capital € 3,000,000 fully paid up
Bologna Register of Companies no. 01033260371
REA (economic administrative index) No. 234613

e-Mail: 3f-filippi@3f-filippi.it
Telephone: +39.051.6529611
Fax: +39.051.775884
Group
Social
lightUpdate
The information, at the speed of Light.
Subscribe to lightUpdate to keep in touch with 3F Filippi: news, events and product news delivered to your mailbox.
Cookie information
ACCEPT
This site uses only technical cookies, including third-party cookies, and does not use any profiling cookies.
In order to access the site, it is necessary to consent to the use of cookies by clicking on the "Accept" button.
For more information on how we use cookies and how to remove them, see our cookie policy.