To replace the 4x55W IP64 version. ON/OFF electronic wiring 230V‑50/60Hz
A5223
Kit LED 3F Cub - 100W/840
108
12988
4000
>80
680x680x187
A5224
Kit LED 3F Cub - 150W/840
159
19764
4000
>80
680x680x187
EP maintained emergency wiring, 1hr duration with 24hrs recharge
A5225
Kit LED 3F Cub - 100W/840 EP
109
12988
4000
>80
680x680x187
A5226
Kit LED 3F Cub - 150W/840 EP
160
19764
4000
>80
680x680x187
DALI electronic wiring 230V‑50/60Hz
A5227
Kit LED 3F Cub - 100W/840 DALI
108
12988
4000
>80
680x680x187
A5228
Kit LED 3F Cub - 150W/840 DALI
159
19764
4000
>80
680x680x187
DALI ‑ EP maintained emergency wiring, 1hr duration with 24hrs recharge
A5229
Kit LED 3F Cub - 100W/840 DALI EP
109
12988
4000
>80
680x680x187
A5230
Kit LED 3F Cub - 150W/840 DALI EP
160
19764
4000
>80
680x680x187
Kit LED Retrofit 3F Cub IP64 CR
To replace the 4x55W IP64 CR version. ON/OFF electronic wiring 230V‑50/60Hz
A5231
Kit LED 3F Cub CR - 100W/840
108
12988
4000
>80
680x680x187
A5232
Kit LED 3F Cub CR - 150W/840
159
19764
4000
>80
680x680x187
EP maintained emergency wiring, 1hr duration with 24hrs recharge
A5233
Kit LED 3F Cub CR - 100W/840 EP
109
12988
4000
>80
680x680x187
A5234
Kit LED 3F Cub CR - 150W/840 EP
160
19764
4000
>80
680x680x187
DALI electronic wiring 230V‑50/60Hz
A5235
Kit LED 3F Cub CR - 100W/840 DALI
108
12988
4000
>80
680x680x187
A5236
Kit LED 3F Cub CR - 150W/840 DALI
159
19764
4000
>80
680x680x187
DALI ‑ EP maintained emergency wiring, 1hr duration with 24hrs recharge
A5237
Kit LED 3F Cub CR - 100W/840 DALI EP
109
12988
4000
>80
680x680x187
A5238
Kit LED 3F Cub CR - 150W/840 DALI EP
160
19764
4000
>80
680x680x187
ILLUMINOTECHNICAL
Wide symmetric distribution.
Lifetime (L70/B20): 100000 h. (tq+25°C)
Lifetime (L70/B10): 50000 h. (tq+40°C)
Photobiological safety RG0.
SOURCE
Linear LED modules.
Colour initial tolerance (MacAdam): SDCM 3.
MECHANICAL
Aluminium gear‑tray unit.
Tamper‑proof closures (2 pieces) to replace the two existing ones.
ELECTRICAL
In compliance with EN 60598‑1.
Compliance with the EN 60598‑2‑22 standard for power supply from a centralised CPSS emergency system must be verified in the technical data sheets of each individual device on our website.
The luminaires with EP permanent emergency wiring on board comply with EN 60598‑2‑22 standard, high risk areas excluded.
Single‑circuit wiring.
INSTALLATION
Retrofit.
Correct installation of the retrofit LED kit, compliant with EN 60598‑1 and CE marked, inside the 3F Filippi ‑ 3F Cub Fluorescent luminaires must be only performed by qualified personnel to ensure compliance with the national installation standards.
NOTES
Evaluate the use of moulded anti‑glare glass according to the application.
WARNING
Fixture not suitable for cold stores with an ambient temperature <0°C and/or relative humidity >85%.
In order to maintain the degree of protection of the device and for the purposes of validity of the guarantee of the new retrofit kits, it is imperative:
- follow the safety and operating instructions described in the installation instructions
- the use of the two self‑drilling screws supplied (one for each driver), will perform the dual function of drilling the body and fixing the driver, while maintaining the fixture's degree of protection
- the replacement of existing tamper‑proof closures with new ones
- clean the screen glass to improve efficiency