Category

3F Hal Direct

Lighting design

Direct symmetric distribution. Average luminance <3000 cd/m² for radial angles >65°. Lifetime (L80/B10): 100000 h. (tq+25°C) Photobiological safety RG0 .

Light source

Linear LED modules and COBs. Colour initial tolerance (MacAdam): SDCM 3.

Mechanical

Body and heads with embossed finish for maximum resistance to touch and scratches. Removable flow recuperator. LGS micro-prismatic flat diffuser in transparent methacrylate (PMMA), multi-lenticular exterior, anti-glare. Anti-glare opal polycarbonate filter for brightness uniformity. Spotlight version Invisible interior spot in central position (75 mm version) or lateral position (150 and 300 mm verions), for accent or service lighting. Internal parabolic element in black aluminium.

Electrical

In compliance with EN 60598-1. Compliance with the EN 60598-2-22 standard for power supply from a centralised CPSS emergency system must be verified in the technical data sheets of each individual device on our website. 5-pole terminal block, single 230V circuit, 2 DALI addresses (depending on the type of lighting fixture). 5-pole transparent power cable protrudes by 1.5 m with sheared end.

Installation

Ceiling mounted or suspension installation.